Why do boilers in old steamships had tie rods bolted only in the upper part and not in the lower part? - Quora
![Tentative revised boiler safety orders. ove ma^ also be incrcas^^i15 per cent. When two sheets are connected by stays and but one of thesesheets requires staying, the value of C is Tentative revised boiler safety orders. ove ma^ also be incrcas^^i15 per cent. When two sheets are connected by stays and but one of thesesheets requires staying, the value of C is](https://c8.alamy.com/comp/2AFRFY7/tentative-revised-boiler-safety-orders-ove-ma-also-be-incrcasi15-per-cent-when-two-sheets-are-connected-by-stays-and-but-one-of-thesesheets-requires-staying-the-value-of-c-is-governed-by-the-thicknessof-the-sheet-requiring-staying-52-report-of-boiler-code-committee-amsocme-acceptable-proportions-for-the-ends-of-through-stays-withwashers-are-indicated-in-fig-14-200-stayholts-the-ends-of-screwed-staybolts-shall-be-rivetedover-or-upset-by-equivalent-process-the-outside-ends-of-solidstaybolts-8-in-and-less-in-length-shall-be-drilled-with-a-hole-atleast-316-in-diameter-to-a-d-2AFRFY7.jpg)
Tentative revised boiler safety orders. ove ma^ also be incrcas^^i15 per cent. When two sheets are connected by stays and but one of thesesheets requires staying, the value of C is
![Boiler safety orders. e stress per square inch net crosssectional area of stays and staybolts shall be as given in Table 4. The length of the stay between supports shall be Boiler safety orders. e stress per square inch net crosssectional area of stays and staybolts shall be as given in Table 4. The length of the stay between supports shall be](https://c8.alamy.com/zooms/9/5f424f37de5943fdb902c314ca184e7a/2ag1f4n.jpg)
Boiler safety orders. e stress per square inch net crosssectional area of stays and staybolts shall be as given in Table 4. The length of the stay between supports shall be
![Tentative revised boiler safety orders. quired cross-sectional area of the brace. 224 Gusset stays when constructed of triangular right-angledweb plates secured to single or double angle bars along the two NEW Tentative revised boiler safety orders. quired cross-sectional area of the brace. 224 Gusset stays when constructed of triangular right-angledweb plates secured to single or double angle bars along the two NEW](https://c8.alamy.com/comp/2AFRF4R/tentative-revised-boiler-safety-orders-quired-cross-sectional-area-of-the-brace-224-gusset-stays-when-constructed-of-triangular-right-angledweb-plates-secured-to-single-or-double-angle-bars-along-the-two-new-installations-part-i-section-i-power-boilers-61-sides-at-right-angles-shall-have-a-cross-sectional-area-in-a-plane-atright-angles-to-the-longest-side-and-passing-through-the-intersectionof-the-two-shorter-sides-not-less-than-10-per-cent-greater-thanwould-be-required-for-a-diagonal-stay-to-support-the-same-surfacefigured-by-the-formula-in-par-221-assuming-the-diagonal-stay-isat-2AFRF4R.jpg)